Online sound meter: live decibel readings in your browser
Press Start, allow the microphone, and Reatims shows an A-weighted sound level, updated ten times a second, with min, Leq (average), max and peak hold. It is free, needs no app, and the audio is analyzed on your device only.
Press Start and allow the microphone to see a live reading.
Audio is processed locally in your browser. Nothing is recorded or uploaded.
Readings are estimated dB(A), uncalibrated. Phone and laptop microphones vary by several decibels. For legal, workplace-compliance or medical decisions use a calibrated Class 1 or Class 2 sound level meter. How to calibrate this meter.
How to use the sound meter
- Start and allow. Tap Start meter. Your browser asks for microphone permission; choose Allow. On iPhone, tap once more if Safari shows a prompt.
- Hold the device still. Point the bottom edge (where the phone microphone usually is) toward the sound, at arm's length, away from your body and from surfaces that reflect sound. Avoid covering the mic with a case or a finger.
- Pick the response. Fast (125 ms) follows speech and short events. Slow (1 s) steadies fluctuating noise. Leq is the true energy average since Start and is usually the number to report.
- Read min, Leq, max, peak. Max is the highest time-weighted reading; peak hold is the highest instantaneous sample level, which is always higher on clicks and bangs.
- Calibrate once. If you can borrow a sound level meter, play steady noise, compare, and move the offset slider until both agree. The offset is saved in this browser.
- Export. Export CSV downloads a timestamped log (10 rows per second) that opens in Excel, Numbers or Google Sheets, which is handy for documenting a noise problem.
What happens inside

The browser's Web Audio API passes raw microphone samples to a small processor on this page. Each sample goes through a digital filter that reproduces the A-weighting curve defined in IEC 61672-1:2013 (pole frequencies 20.6 Hz, 107.7 Hz, 737.9 Hz and 12,194 Hz), is squared, and feeds two exponential averages with the standard fast (125 ms) and slow (1 s) time constants. Leq is the energy average of every filtered sample since Start. Reatims asks the browser to switch off echo cancellation, noise suppression and automatic gain control, which would otherwise squash loud sounds and lift quiet ones.
A microphone reports digital values, not pascals, so the page assumes a nominal sensitivity (a full-scale signal reads 100 dB) and adds your calibration offset. That assumption is why the display says uncalibrated. NIOSH researchers who tested smartphone apps found that the best ones came within about ±2 dBA of a reference meter, and closer still with an external microphone; see our summary of smartphone meter accuracy research.
Quick reference levels
| Level (dBA) | Typical source | What it means |
|---|---|---|
| 30 | Whisper, quiet bedroom | WHO bedroom guideline for good sleep |
| 60–70 | Normal conversation | Comfortable, no risk |
| 85 | Heavy traffic, blender | NIOSH 8-hour recommended limit |
| 94–100 | Motorcycle, power tools | 1 h at 94, 15 min at 100 (NIOSH) |
| 110+ | Concert near speakers, siren | Damage possible in minutes |
See the full interactive decibel chart or work out daily limits with the noise exposure calculator.
Volume and hearing safety
If the meter regularly shows more than 85 dBA where you spend hours, or you have to shout to be heard at arm's length, wear hearing protection or reduce the time. Ringing ears after an event is a warning sign. This site is not medical advice; if you notice hearing changes, see an audiologist or doctor.
Frequently asked questions
How accurate is an online sound meter?
With processing switched off, a phone or laptop microphone typically reads within a few decibels of a real meter in the 40–90 dB range once you set the calibration offset. Uncalibrated, readings can be 5–10 dB off, which is why every number here is labeled as an estimate.
Does Reatims record or upload my audio?
No. The browser hands microphone samples to a small audio processor running on this page, which turns them into a level number and throws the samples away. Nothing is recorded, stored or sent to a server. The only thing saved is your calibration offset, in your own browser.
Why does the reading say dB(A)?
The meter applies the A-weighting curve from IEC 61672-1, which turns down low and very high frequencies roughly the way human hearing does at moderate levels. Workplace limits from OSHA and NIOSH are written in dBA, so it is the most useful default.
What is the difference between fast and slow response?
Fast uses a 125 ms time constant and follows quick changes such as speech or a door slam. Slow uses 1 second and gives a steadier number for fluctuating noise like traffic. Leq, the energy average since you pressed Start, does not depend on this setting.
Why will my iPhone not start the meter?
Safari asks for microphone permission each time unless you allow it in Website Settings, and it only starts audio after a tap. If you tapped Block, open aA → Website Settings → Microphone → Allow and reload. In-app browsers inside social apps often cannot use the microphone at all; open the page in Safari.
What noise level is harmful?
NIOSH recommends keeping exposure under 85 dBA averaged over 8 hours and halving the time for every 3 dB above that. Short exposure to very loud sound, such as fireworks near 140 dB, can cause damage immediately.
More audio tools
- AnalyzerSpectrum analyzer
See which frequencies make up a sound, live, with a dominant-pitch readout.
- GeneratorTone generator
Play sine, square, triangle or sawtooth tones with a safe volume limiter.
- GeneratorWhite, pink & brown noise
Steady masking noise for sleep or focus, with a fade-out timer.
- CalculatorNoise exposure calculator
Daily allowed time, noise dose and TWA under both NIOSH and OSHA criteria.
- CalculatorDecibel add & subtract
Combine several noise sources, or subtract background noise from a reading.
- CalculatorDistance attenuation
Inverse-square law: predict the level at a new distance, −6 dB per doubling.
- CalculatorHearing protector NRR calculator
Estimate the level at your ear with earplugs or earmuffs, using OSHA’s method.
- CalculatordB SPL ↔ pascal converter
Convert decibels to sound pressure (Pa) and intensity (W/m²) and back.
- MusicMetronome
Sample-accurate clicks from 30 to 300 BPM, accents, subdivisions, tap tempo.
- MusicChromatic tuner
Detects any note from your mic and shows cents sharp or flat versus A4 = 440 Hz.
- GeneratorFrequency hearing check
Find the highest tone you can hear, at a safe volume. Not a medical test.
Guides
- Calibrate a Phone Sound Meter: Step-by-Step Guide
How to calibrate a phone or laptop sound meter against a Class 1 or 2 meter or a 94 dB calibrator, set the Reatims offset, and know its limits.
- Common Noise Levels: Decibels of Everyday Sounds
Approximate decibel levels of everyday sounds, from conversation to sirens and fireworks, based on NIDCD and CDC/NIOSH figures, plus how to read them.
- dBA vs dBC: A, C and Z Weighting Explained
What A, C and Z frequency weighting mean, how IEC 61672-1 defines them, when to use dBA or dBC, and how peak, Lmax and Leq readings differ.
- Hearing Protection NRR Explained: What the Number Means
What the Noise Reduction Rating on earplugs and earmuffs means, how OSHA derates it in the field, and how to pick and fit protectors that actually work.
- Kids Hearing Safety: Toys, Headphones and Loud Places
Practical ways to protect children's hearing from loud toys, headphones, and noisy events, based on NIDCD guidance and the WHO-ITU safe listening standard.
- LUFS Loudness Explained: LUFS vs. LKFS vs. dB SPL
What LUFS and LKFS measure, how ITU-R BS.1770 works, the EBU R128 and ATSC A/85 targets, common streaming levels, and why LUFS is not the same as dB SPL.
All guides · Measuring by setting: classroom, office, nursery and more