Noise exposure calculator: NIOSH and OSHA
Enter a sound level to see how long you can be exposed each day, or add several periods to get a full-day noise dose and 8-hour time-weighted average (TWA). Both U.S. criteria are shown side by side because they give different answers.
Allowed time at one level
Full-day dose
Audio is processed locally in your browser. Nothing is recorded or uploaded. This tool does not use the microphone.
This tool is for general information only: it is not medical or legal advice, and results based on phone readings are estimates.
How to use the noise exposure calculator
NIOSH REL (recommended exposure limit, 1998 criteria document): 85 dBA for 8 hours with a 3 dB exchange rate, so allowed time halves every 3 dB. Formula: T = 8 ÷ 2(L − 85)/3 hours. 88 dBA gives 4 hours, 91 dBA 2 hours, 100 dBA 15 minutes.
OSHA PEL (permissible exposure limit, 29 CFR 1910.95 Table G-16): 90 dBA for 8 hours with a 5 dB exchange rate. Formula: T = 8 ÷ 2(L − 90)/5. 95 dBA gives 4 hours, 100 dBA 2 hours. OSHA also requires a hearing conservation program when the 8-hour TWA reaches the 85 dBA action level.
For a mixed day, add rows of level and duration. Dose = Σ (time at level ÷ allowed time at that level) × 100%. A dose over 100% exceeds the criterion. TWA converts the dose back to an equivalent steady 8-hour level: NIOSH TWA = 85 + 10·log10(D/100); OSHA TWA = 90 + 16.61·log10(D/100).
Why they differ: the 3 dB rule follows the equal-energy principle (3 dB is double the sound energy), which NIOSH judged better supported by hearing-loss data. The OSHA 5 dB rule dates from 1971 and assumes recovery during work breaks. NIOSH estimates that 8% of workers exposed at its REL over a working lifetime would still develop hearing loss, versus 25% at 90 dBA.
Examples
- 88 dBA all day: NIOSH allows 4 h, OSHA allows 10.6 h (OSHA counts only levels of 80 dBA and above toward dose).
- 95 dBA: NIOSH 47.6 min, OSHA 4 h.
- 2 h at 95 dBA + 6 h at 80 dBA: OSHA dose 50% + 18.8% = 68.8% (TWA 87.3 dBA); NIOSH dose 252% + 23.6% = 275.6% (TWA 89.4 dBA).
FAQ
Which limit should I follow?
OSHA’s PEL is the legal minimum for most U.S. general-industry employers. NIOSH’s REL is the more protective, research-based recommendation, and many safety programs use it as their target.
Can I use phone readings for OSHA compliance?
No. Compliance measurements need a Type 2 (or better) sound level meter or a noise dosimeter, calibrated, used by a trained person. Use this calculator with phone readings only for a rough sense of risk.
What about impulse noise like gunshots?
Both criteria cap impulsive or impact noise at 140 dB peak sound pressure level. Phone microphones cannot measure such peaks accurately.
Does hearing protection change the result?
Yes. Estimate the level under your protector with the NRR calculator, then enter that lower level here.
Sources
Related tools
- CalculatorHearing protector NRR calculator
Estimate the level at your ear with earplugs or earmuffs, using OSHA’s method.
- CalculatorDecibel add & subtract
Combine several noise sources, or subtract background noise from a reading.
- CalculatorDistance attenuation
Inverse-square law: predict the level at a new distance, −6 dB per doubling.
- CalculatordB SPL ↔ pascal converter
Convert decibels to sound pressure (Pa) and intensity (W/m²) and back.
- MeterLive sound meter
Real-time dB(A) with min, Leq, max and CSV export.